A Vance company - serving Roswell, GA

Before & After Gallery - Vance Gate Repair Roswell

Every visit starts with

Free on-site gate assessment - hinges, posts, and your LiftMaster or Nice gate operator checked before anything is quoted

The assessment is free and the quote is the invoice.

Styles & brands we work with

Wrought iron
Wrought iron
Wood & steel frame
Wood & steel frame
Farm & ranch
Farm & ranch
Sliding driveway gates
Sliding driveway gates
LiftMaster operators
LiftMaster operators

Before & after – our own jobs

Before - Recent ProjectBeforeAfter - Recent ProjectAfter
Recent Project
Before - Full RestorationBeforeAfter - Full RestorationAfter
Full Restoration
Before - Complete UpgradeBeforeAfter - Complete UpgradeAfter
Complete Upgrade

Gate Repair Before & After in Roswell, GA

We’ve documented every gate we’ve touched in Roswell since 2014. The photo records live in our job files, and now we’re pulling a few into the light. These aren’t stock images. They’re what we actually found, what we actually did, and how the gate left our hands.

Call (706) 928-9815

Recent Transformations

Sagging Wrought-Iron Driveway Gate - Structural Rebuild

Wrought iron driveway gate sagging on hinge side with visible gap at latch
Before: Hinge-side sag on a 16-foot wrought-iron estate gate, Roswell Mill area.
Same wrought iron gate realigned with new j-bolt hinges and level top rail
After: Gate rehung on new j-bolt hinges, top rail leveled, latch catching clean.

The gate had sagged four inches on the hinge side over fifteen years. The original builder had used light-duty barrel hinges on a 400-pound leaf. We cut off the old hinge plates, welded in 3/4-inch j-bolt hinges with grease zerks, and shimmed the post plumb. The top rail had bowed from the uneven load, so we heated and straightened it in place rather than replacing the whole frame. Gate swings one-handed now. Under Clause 4, the customer has photos of the hinge weld penetration and the level reading.

LiftMaster LA500 Gate Opener - Dead Motor Replacement

LiftMaster LA500 gate operator with control board removed and wiring exposed
Before: LiftMaster LA500 with seized arm motor, no response at keypad or remote.
Replacement motor installed with new wiring harness and documented limit settings
After: New OEM motor, harness, and limit switch assembly installed and programmed.

The motor had drawn excessive amperage until it cooked the windings, probably from a partially seized gate that the previous company kept adjusting around instead of fixing. We replaced the motor with an OEM unit, not a generic swap. The arm bracket bolt pattern was wallowed out, so we drilled and tapped new threads rather than forcing the old ones. Set the limit switches with a protractor, not by eye. The photo log shows the amp draw at 3.2 under load, well within spec. Customer’s remotes relearned without issue.

FAAC 415 Slide Gate - Chain Jump and Track Wear

FAAC 415 slide gate with chain off sprocket and visible track gouging
Before: Chain off the drive sprocket, track gouged from repeated misalignment.
FAAC 415 with new chain, dressed track, and adjusted chain tensioner
After: New #40 roller chain, dressed track edges, tensioner set to factory spec.

The chain had jumped three times in two months. Each jump drove the gate off the track and chewed the steel. We found the tensioner frozen at its minimum extension and the idler sprocket worn to a hook profile. Replaced chain, sprocket, and tensioner. Dressed the track edges with a flap disc so the rollers wouldn’t catch. The real fix was finding why the gate was binding mid-travel: a root had lifted the concrete footing 3/8 inch. We shimmed the track bracket, didn’t just sell a new operator. Gate runs quiet now. The root’s noted in the file for next year’s check.

Aluminum Pool Gate - Hinge Tear-Out and Self-Closing Failure

Aluminum pool gate with hinge screws pulled through frame and gate dragging
Before: Hinge screws pulled through hollow aluminum frame, gate dragging on coping.
Aluminum pool gate with through-bolted hinge plates and adjusted spring closer
After: Through-bolted hinge plates with backing washers, spring closer reset to 4.5 lb closing force.

Pool code in Roswell requires self-closing and self-latching from any position. This gate had neither. The original installer had run sheet-metal screws into hollow tube, which pulled out in less than two seasons. We through-bolted with 1/4-inch stainless hardware and aluminum backing plates inside the tube. Reset the spring closer to 4.5 pounds, which is the minimum to close against the hydraulic resistance of a wet gate. Latch height corrected to 54 inches per code. Inspector passed it clean the next morning.

Viking G-5 Swing Gate - Control Board Lightning Damage

Viking G-5 control board with scorched terminal block and melted fuse holder
Before: Viking G-5 control board after surge damage, fuse holder melted to the enclosure.
Replacement control board with surge suppressor and properly torqued terminal connections
After: New board, surge suppressor on the 24V transformer, all terminals torqued to spec.

Lightning hit the transformer feeding this property, not the gate directly. The surge came in on the low-voltage side and found the path of least resistance through the control board’s ground plane. We replaced the board, but more importantly traced every conductor for hidden damage. The loop detector coax had arc-burned through its shield at the splice. Replaced that too, not just the obvious failure. Installed a surge suppressor on the transformer secondary. Documented resistance readings on each winding before we closed the enclosure. Gate’s had two storm seasons since, no callbacks.

Custom Fabricated Estate Gate - Rusted Lower Rail Replacement

Ornamental estate gate with rusted through lower rail and peeling powder coat
Before: Lower rail rusted through at grade level, powder coat failing from moisture wicking.
Gate with new 2x2 solid steel lower rail, welded and re-powder coated to match
After: New 2×2 solid steel lower rail, fully welded, re-coated to match existing finish.

The original rail was 16-gauge square tube with a weep hole that clogged. Water sat inside for years. We cut out the compromised section and welded in 2×2 solid bar, which won’t hold moisture and gives the pickets something rigid to weld to. Ground the welds flush, not just capped over. The customer wanted to keep the existing scrollwork, so we preserved every piece, numbered them during disassembly, and reattached in order. Sent the whole leaf out for powder coat in a custom mix to match the undamaged upper section. Gate’s heavier now, but it’ll outlast the original by decades.

Want Results Like These?

Technician installing a gate lock mechanism with tools on a mat
Want Results Like These?

Every job here started with a phone call to a live person, not a form or a callback queue. We’ll look at your gate, write the price before any work starts, and leave you with the same photo record we file in our system. If something’s not right in the next year, we’ll make it right. No argument, no fee.

Call (706) 928-9815 now. Estimates are free, and we answer 24 hours a day.

Written by Adrian Vance, Owner at Vance Gate Repair Roswell, serving Roswell since 2014.

Need Gate Repair help in Roswell? Licensed & insured · 60-minute response · free estimates
Call (706) 928-9815
Local Service Coverage

Request a Free Estimate in Roswell

Tell us what you need - Vance Gate Repair Roswell responds fast. No obligation.

By reaching out through this form, you agree to the terms of our Privacy Policy and agree to be contacted via phone, email, or SMS about your request, including by the independent professionals who may fulfill it.

Prefer to text? Text Now